Comm-Tec EIB Manual de usuario

Busca en linea o descarga Manual de usuario para Gateways / Controladores Comm-Tec EIB. Comm-Tec EIB User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
- 1 -
User Manual
for the
COMM-TEC EIB Gateway
CTG-KNX/IP (v1.0.1)
Vista de pagina 0
1 2 3 4 5 6 ... 21 22

Indice de contenidos

Pagina 1 - User Manual

- 1 -User Manualfor theCOMM-TEC EIB GatewayCTG-KNX/IP (v1.0.1)

Pagina 2 - Table of contents

- 10 -Command DescriptionEIS5? <No> Inquiry EIS5 valueConverts the 2Byte raw data into ASCII string with floating pointNote: Only valid for actu

Pagina 3 - 1 Introduction

- 11 -3.3.2 Feedback from moduleThe feedback is always in STRING format.The module can generate the following feedback:StringDescriptionDATE=<No>

Pagina 4 - NetLinx Master

- 12 -Command DescriptionADR_<Value> Definition of output format of EIB group address(Main/medium/sub group OR main group/sub group)<Value>

Pagina 5

- 13 -Command DescriptionLIST_<No>-<No2> List actuators in the range of <No> to <Nr2> (AMX numbers) with EIB group address,cur

Pagina 6 - 2 Hardware

- 14 -3.3.4 Channels and levelsAll addresses are available as channels. The current value is displayed on the corresponding channels of thevirtual dev

Pagina 7 - 3 Programming

- 15 -5 Appendix A – Sample program5.1 Notes EIB tableAll actuators to be switched/set/controlled are to be introduced to the gateway. This is achieve

Pagina 8

- 16 -5.2.1 Example 1 – Structure of EIB table with functions from EIB_Tools.AXIStart delay, module reports ready for ADDStartSet light 1Set light 2Se

Pagina 9

- 17 -5.2.2 Example 2 - Structure of EIB table with SEND_COMMANDSStart delay, module reports ready for ADDStartSet light 1Set light 2Set light 3Light

Pagina 10 - Command Description

- 18 -5.2.3 Example 3 – Enter addresses from fileThe address table can be read and generated from file on CF card. The reading of the file can for ins

Pagina 11 - Description

- 19 -5.2.4 Example 4 – Main programfeedback array for max 3000 addressesLight 1 ONAnalog actuator 50%Dimmer brighterfeedback for light 1 (see EIB tab

Pagina 12

- 2 -Table of contents1 Introduction...

Pagina 13

- 20 -6 Appendix B – EIB_Tools.AXIWe recommend not to use the send commands directly, but always utilize the functions of this include file. Thecompil

Pagina 14 - 4 Data Types

- 21 -7 Appendix C – Comparison with previous versionThe general operation of hardware and software has not changed. A filter table has still to be ge

Pagina 15 - 5 Appendix A – Sample program

- 22 -8 Appendix D – What to do if it does not work?The following table provides tips for error definition, in case it does not work.This serves a qui

Pagina 16

- 3 -1 Introduction1.1 AimsThe software module is being used to connect AVIT and AMX control systems to the "EuropeanInstallation Bus" EIB (

Pagina 17

- 4 -Figure 1 – Process of CommunicationNetLinx MasterEIBGatewayNetLinxModuleNetLinxProgramVirtualDevice

Pagina 18

- 5 -1.4 EIB details when using the GatewayIn principle, the EIB gateway CTG-KNX/IP is a normal EIB device, and can therefore be connected atany locat

Pagina 19

- 6 -2 Hardware2.1 Interfaces, Indication and Operating DevicesConnections :230 V EIBRJ45LEDs : Busspannung flashes when bus voltage drops below 15V

Pagina 20 - 6 Appendix B – EIB_Tools.AXI

- 7 -3 Programming3.1 Integrating the ModuleAt first, the program needs to get the information, what the Gateway’s IP-Address is.This can be done by t

Pagina 21 - 7.3 Feedback

- 8 -on an „AMX number between 1 and 3000. Communication with the actuators concerned is only madevia this number.This tabel is integrated with the fo

Pagina 22

- 9 -3.3 The NetLinx module interface3.3.1 Commands for moduleCommands to the module always take place per SEND_COMMAND to the virtual device.The modu

Comentarios a estos manuales